Українська    Русский    English
   Search
Engineering | Projects | Modernization
Engineering
Products
Heaters
Sectional heat exchangers
Steam contact heaters
Scrubbers Venturi
Barometric condensers
Steam separators
Steam-jet compressor
Precipitation tank
Hot liming device
Evaporator
Сandle filter
Steam contact heaters
Steam contact heater (draft) Steam contact heaters are meant to heat liquids within direct contact with heating steam.

Various potential steam can be used including low-pressure steam (indirect steam of last section of evaporation steam, fillmass steam) can be used as heat- transfer agent. The steam potential is defined according to the temperature up to which the liquid should be heated. Underheating of liquid up to the temperature of heating steam - approximately 10С.

The steam contact heaters are mainly used to heat water. They also can be applied to heat liquids with low solid content, for which impoverishment of solids is not critical value.

The steam heaters can have various liquid deliberation system (jet, jet-cascade, film) depending on the type of liquid and heating medium.

The steam contact heater consists of body 1, water deliberation system 2, heat-transfer agent inlets 3 and uncondensed gas extractions 4.

TECHNICAL SPECIFICATIONS
Figures Measurement
units
TK-PKP-100A TK-PKP-60 TK-PKP-100M TK-PKP-180 TK-PKP-200 TK-PKP-300 TK-PKP-50 TK-PAV-50
1 Water consumption t/h 100 60 100 180 200 300 50 50
2 Heat-transfer agent - indirect steam of last section of evaporation steam fillmass steam
3 Temperature of water 0С 65-75 85-90 65-75 65-90 65-75 65-90 50-80 45-50
4 Pressure of water (min) MPa 0,12   0,12
5 Pressure in a heater MPa 0,038   0,02-0,015
6 Dimensions:
width (s)
length (l)
height (h)
mm 1620
1520
3220
1220
1175
2300
1420
1420
2890
1420
1420
2890
1820
1820
3900
2000
1762
3000
1240
1246
2400
1420
1320
3120
7 Weight kg 1170 660 376 376 1825 445 844 905